Farran

Need Help? Talk to an expert

+353-21-484-9170

Why Your Antenna Test Setup Is Quietly Failing You at mmWave Frequencies

The test infrastructure that carried engineers through 4G and early 5G is showing its age — and most labs haven’t noticed yet. There’s a quiet crisis playing out in RF test labs around the world. Engineers are running the same test methodologies they’ve used for years, on equipment that served them well through previous wireless generations, and getting results they half-trust on devices that operate at frequencies their tools were never designed to reach. Nobody is sounding alarm bells because the problem doesn’t announce itself with a dramatic failure. It creeps in — a radiation pattern that looks slightly off, a gain measurement that seems plausible but can’t be fully trusted, a compliance test that passes on the bench and surprises in the field. By the time the issue becomes obvious, the cost in time, re-spins, and credibility is already significant. The root of the problem is straightforward: millimeter wave antenna testing is fundamentally different from anything that came before it, and the industry’s test infrastructure hasn’t fully caught up.   The World Has Changed. Most Test Labs Haven’t. For most of wireless history, testing an antenna was conceptually simple. You connected a cable to a port, ran your measurements with a vector network analyser, and characterised the device under test. The antenna and the radio circuitry were separate enough that you could evaluate them independently. This worked well from VHF through 4G, through sub-6 GHz 5G, and it gave engineers a reliable playbook. At mmWave frequencies — the bands that define 5G FR2 and where 6G research is now focused — that playbook breaks down. The short wavelengths involved mean that the RF front-end circuitry and the antenna cannot be accurately characterised in isolation from one another. As one industry analysis summarised it, at mmWave frequencies, the MMIC and antennas cannot be accurately measured independently, and any testing requires a radiated over-the-air (OTA) measurement. The cable-based “conducted test” that defined decades of antenna measurement simply isn’t viable anymore. This single shift changes everything about how tests must be set up, what equipment is required, and what “accurate results” actually looks like.   What Makes mmWave Testing So Different? You can’t use a cable. At frequencies above 24 GHz, the connection between instrument and device under test is no longer a practical option. Connectors introduce loss, the cable itself becomes a significant source of error, and many modern 5G components don’t have a test connector at all. Every measurement at these frequencies must happen over the air — which means controlled RF environments, precision positioning, and equipment that can operate at the frequency of the device being tested. The test distance changes. In lower-frequency testing, far-field measurements require large physical separation between source and device. At mmWave frequencies, because wavelengths are shorter, far-field conditions are achieved at much smaller distances — often just one to two metres. This sounds like an advantage, and in terms of chamber size it is. But it also means that any stray reflections within a compact chamber are far more problematic. Internal reflections that would be negligible at lower frequencies can seriously compromise measurement accuracy at mmWave. The antenna and radio are inseparable.Modern mmWave devices — 5G modules, phased array units, automotive radar sensors — integrate the antenna directly with the RF circuitry. Beamforming, which steers energy in specific directions to overcome path loss, is baked into the device at the hardware level. To characterise how that device actually behaves, you have to measure its full three-dimensional radiation pattern, not just a single port response. That requires test systems that can measure gain, polarisation, and beam behaviour across a full spherical measurement space. The frequencies themselves demand better instruments. The majority of commercially available vector network analysers natively operate up to around 50 GHz. Above that — the E-band (71–86 GHz), W-band (75–110 GHz), and beyond toward the sub-THz frequencies being explored for 6G — standard instruments simply cannot reach. Testing in these bands requires frequency extension hardware that can bring measurement capability up to the frequency of interest without sacrificing accuracy or dynamic range.     What Insufficient Testing Actually Costs The engineering consequences of inadequate mmWave test capability tend to show up in predictable ways. Measurement errors compound into design errors. If a gain measurement is inaccurate by even a few dB at mmWave frequencies, the link budget calculations built on that measurement will be wrong. A system designed around optimistic antenna performance may work acceptably in ideal lab conditions and fail to meet requirements in real-world deployments — a problem that only emerges after significant investment in hardware, integration, and field testing.   Late-stage compliance failures are expensive. When a device reaches OTA compliance testing and the results don’t match what was measured on the development bench, the investigation costs time that production schedules don’t have. Re-spins at this stage are costly not just financially, but in the delay they introduce to product programmes.   The frequency bands keep shifting. 5G FR2 currently spans 24–71 GHz. 6G research is actively exploring frequencies well above 100 GHz, with the D-band (110–170 GHz) drawing particular industry attention. Test infrastructure bought today needs to be capable of reaching those frequencies — either natively or through extension — or it will need to be replaced again within a development cycle or two.   The Upgrade Path That Most Labs Overlook The response to mmWave test requirements doesn’t have to mean emptying a capital budget on entirely new systems. The more practical approach — and the one increasingly adopted by serious test organisations — is frequency extension. A frequency extender integrates with an existing VNA and translates its measurement capability up to the mmWave band of interest. The extender heads can be positioned physically close to the device under test, which minimises cable loss and improves dynamic range precisely where it matters most. For antenna pattern measurement specifically, transmitter and receiver extension modules can be mounted on the positioner arms within a compact anechoic chamber, giving

frequency extenders heads

Unlocking Precision in Antenna Testing: High-Performance Frequency Extension Solutions

By Kathy Stapleton,  Marketing Manager at Farran Technology Farran Technology provides state-of-the-art Antenna Extender Transmitters (AET), Antenna Extender Receivers (AER), and Frequency Extension Heads for Vector Network Analyzers (VNAs) to enhance mmWave testing capabilities. These Antenna Testing solutions extend the frequency range of standard test equipment, offering high sensitivity and cost-effective alternatives to full system upgrades.   Introduction As wireless communication, automotive radar, and millimeter-wave applications continue to evolve, the need for precise and reliable antenna testing has never been greater. Engineers and researchers require accurate tools to measure antenna gain, return loss, and radiation patterns to ensure optimal performance. The Importance of Accurate Antenna Testing Antenna characterization is crucial in industries such as telecommunications, automotive radar, security, and spectrum monitoring. Without precise measurements, performance inconsistencies can lead to signal degradation, reduced efficiency, and compliance failures. Key parameters in antenna testing include: Gain Measurement: Evaluates how efficiently an antenna converts input power into radio waves. Return Loss Measurement: Determines the amount of power reflected back, ensuring minimal signal loss. Radiation Pattern Analysis: Defines the directional distribution of radiated power, crucial for beamforming applications. Farran’s High-Performance Solutions for Antenna Testing Image 2 – Source: Farran Technology Database   Test & Measurement (VNA Frequency Extension Heads) Enhanced Precision for mmWave Antenna Testing Farran’s Frequency Extension Heads seamlessly integrate with VNAs, providing high-accuracy gain and return loss measurements across a wide frequency range. These solutions enable engineers to push the limits of their existing test setups without requiring a complete system overhaul. Key Benefits: Extends frequency coverage for VNAs up to 500 GHz. Ensures high-quality gain and return loss measurements. Enables seamless integration with existing test setups. Antenna Extender Transmitters (AET) Cost-Effective Solutions for Antenna Gain Measurements The AET series delivers high-frequency, stable signals, making them ideal for antenna gain testing. By transmitting precise mmWave signals, AET solutions provide a reliable yet cost-effective alternative to more expensive test systems. Key Benefits: Affordable yet high-performance alternative for gain measurements. Stable high-frequency transmission for accurate testing. Compact and efficient design for ease of integration. Antenna Extender Receivers (AER) High-Sensitivity Solutions for Accurate Antenna Testing Farran’s AER solutions are designed for low-noise, high-sensitivity measurements, ensuring superior accuracy in antenna testing applications. These receivers enhance measurement capabilities in demanding test environments, delivering precise data for performance validation. Key Benefits: Optimized for low-noise performance and high sensitivity. Accurate antenna pattern and gain measurements. Ideal for demanding test setups where precision is critical. Conclusion Farran Technology’s AET, AER, and Frequency Extension Heads provide engineers with the necessary tools to perform precise antenna gain, return loss, and radiation pattern measurements. These solutions enhance the capabilities of existing test equipment while offering cost-effective, high-accuracy alternatives to full system replacements. With seamless integration, extended frequency coverage, and superior sensitivity, Farran’s antenna testing solutions empower industries to achieve unmatched precision in their mmWave applications. Get in Touch For more information on how Farran’s antenna testing solutions can support your application, contact us at sales@farran.com or visit www.farran.com